Characteristics: Suitable for the measuring of the electric medium;Waterproof, resistance to shock;On-line type measurement: full circulation and no block;A wide range of full scale flow rate setting, with bidirectional measurement; Easy installation, can be horizontal, vertical and inclined installed. High accuracy; Selecting the appropriate electrode and lining material, good corrosion resistance and wear resistance.
Profile: Electromagnetic flow meter is designed according to Faraday’s Law of Electromagnetic Induction, it installs a pair of detecting electrodes on the tube wall, where measuring tube axis and magnetic line of force are vertical. When the conductive liquid flows through the alternating magnetic field along the measuring tube (magnetic line of force and the direction of liquid flowing are vertical), the conductive liquid cuts the magnetic line of force, and produces induction electromotive force. Through the two detecting electrodes on the measuring tube, we can detect the induction electromotive force, and work out the rate of flow by the formula below, finally it transforms
the induction electromotive force into 4-20mA and exports it.
FEA11 integrated electromagnetic flowmeter connects the measuring part and transforming part together, it is on-line measurement, observation and operation are convenient. Flowmeter can adjust to different medium measurement through selection of electrode and lining material. The instrument operation using all smart menu, which is convenient
to adjust.
FEA11 integrated electromagnetic flowmeter is suitable for many kinds of conductive liquid’s flow rate measurement,
when selecting, pay attention that the conductivity of the measuring medium should bigger than 5μs/cm(the
conductivity of tap water is about 100-150μs/cm). The instrument is connected by flange.
The main technical parameters
Dimensions
Rated pressure
(MPa)
|
Diameter
(mm)
|
Instrument dimensions
|
Flange connection size
|
W
|
H
|
D
|
b
|
K
|
n-Φd
|
4.0
|
10
|
160
|
360
|
90
|
16
|
60
|
4-Φ14
|
15
|
160
|
360
|
95
|
16
|
65
|
4-Φ14
|
20
|
165
|
360
|
105
|
20
|
75
|
4-Φ14
|
25
|
200
|
360
|
115
|
25
|
85
|
4-Φ14
|
32
|
200
|
370
|
140
|
32
|
100
|
4-Φ18
|
40
|
200
|
370
|
150
|
40
|
110
|
4-Φ18
|
50
|
200
|
385
|
165
|
50
|
125
|
4-Φ18
|
65
|
250
|
400
|
185
|
65
|
145
|
4-Φ18
|
80
|
250
|
415
|
200
|
80
|
160
|
8-Φ18
|
1.6
|
100
|
250
|
440
|
220
|
100
|
180
|
8-Φ18
|
125
|
250
|
465
|
250
|
125
|
210
|
8-Φ18
|
150
|
300
|
497
|
285
|
150
|
240
|
8-Φ22
|
1.0
|
200
|
350
|
550
|
340
|
200
|
295
|
8-Φ22
|
250
|
400
|
580
|
395
|
250
|
350
|
12-Φ22
|
300
|
500
|
643
|
445
|
300
|
400
|
12-Φ22
|
350
|
500
|
704
|
505
|
350
|
460
|
16-Φ22
|
400
|
600
|
764
|
565
|
400
|
515
|
16-Φ26
|
450
|
600
|
814
|
615
|
450
|
565
|
20-Φ26
|
500
|
600
|
860
|
670
|
500
|
620
|
20-Φ26
|
600
|
600
|
968
|
780
|
600
|
725
|
20-Φ30
|
700
|
700
|
1077
|
895
|
700
|
840
|
24-Φ30
|
800
|
800
|
1188
|
1015
|
800
|
950
|
24-Φ35
|
Caliber
|
DN10~1000
|
Power supply
|
24VDC, 220VAC
|
Measurement error
|
0.25, 0.5(distinguished by caliber)
|
Communication
|
RS485 or HART
|
Output signal
|
4~20mA, pulse(5000pulse/s), high/low double limit alarm(capacity 0.2A/50V)
|
Rated pressure
|
1.0MPa, 1.6MPa, 4.0MPa
|
Electrode material
|
Stainless steel containing molybdenum
|
Grounding ring material
|
Polyurethane rubber
|
Lining material
|
SUS304
|
Media
|
Conductive liquid
|
Media conductivity
|
>5μs/cm
|
Flow rate range
|
0.05~12m/s
|
Connection type
|
Flange, dimensions are in the table above
|
Display
|
Backlight LCD
|
Media temperature
|
0~70℃
|
Environment
|
-5~75℃, ≤95%RH, avoid corrosive gas
|
Protection class
|
IP65
|
|