WIO10 Series Side-mounted Water in oil Controller

Characteristics: Accurate and reliable capacitive measurement. Measuring the percentage of water in oil as low as 1%. Smart: with analogue output function. The surface of probe is isolated, can avoid the accidental alarm of little water soaking, two pairs of contacts can be selected. We provide two types for customers: WIO11 integrated type and WIO12 split type. The watch window can be selected.

Profile

WIO10 side-mounted oil in water controller is based on capacitive measuring principle, it is accurate and reliable, and the detecting ratio of oil mixing in water is under 1%. WIO10 side-mounted oil in water controller can be used widely for monitoring the water content in a variety of oil. To measure accurately, for static oil, it must be installed in the bottom of the container. The WIO10 series include WIO11 integrated type and WIO12 type. The probe of WIO12 doesn’t need to be dismantled during usage, it makes convenience for the maintain and  replacement of controller. 

WIO oil in water controller is based on the principle that capacitance is linear changing with the change of the electric inductivity when the capacitance is not change in other conditions but the electric inductivity between two poles changes. The capacitance two poles of the controller is composed by probe case and inner core, which can be seen in figure 1. When the oil mixing with water between two poles the electric inductivity will be changed, which will cause the capacitance changing, the proportion of oil mixing with water is set by microcircuit, when the proportion up to the setting value, the controller will export alarm contact signal.

Our company uses commonly used configuration as  the standard, at the same time, we add with extended special requirements for you to choose, if it still couldnot meet your requires, please list us your photos and tables.

The main parameters:

Product Standard Table:

Num
Configuration type
Configuration name
1
Working voltage
24VDC
2
Probe material
Brass
3
Output type
1 pair open and close contact
4 Length of probe 110mm, (G1/2')
5 Watch window Non

Particular Requirements for Product List:

Code
Configuration type
Configuration name
T11
Working voltage
220VAC/DC
T21
Probe material
Stainless steel
T31
Output type
2 pair open and close contact
T41 Length of probe 80mm, (G3/8')
T51 Watch window Selectable
T00
Special requires
Pls list photos

Probe length
110mm
Working voltage
24VDC, 220VAC/DC
Max power consumption
1.5W (12~36VDC), 3W (220VAC/DC) T31 type 3W(24VDC), 5W(220VAC/DC)
﹡Output type
1 pair open and close contacts. T31 type: 2 pairs
Contact capacity
3A/24VDC, 1A/220VAC/DC
Probe material
Brass, 304 stainless steel
Wiring type
Thread
Environment
-10~80℃, ≤95%RH, avoid corrosive gas
Protection class
IP65
Configurable items
Intelligent transmitter


Introduction of parts:

1 WW Smart transmission controller

The transmission controller can transform the proportion of oil mixing with water into corresponding standard analog signal and export related contact signal. It exports alarm and control signal when it exports analog signal, users can choose different transmitter according to the site requirements. This series transmitter includes WW series of intelligent transmission controller, more features can be seen below.
WW series of intelligent transmission controller added the microelectronics smart chip to make it intelligent. WW series of intelligent transmission controller has a human friendly interface. It can freely set the parameters, self–tuning, self-diagnostic alarm output, and can achieve up to 4 pairs of relay control output contacts. It also has the function of LED or LCD display.
Our company specially selects this series of transmitter’s standard configuration and parameters, if you have other requires, please list us your photos and tables by special requirements.
Product Standard Table:
Num
Configuration type
Configuration name
1
Working voltage
24VDC
2
Display type
LED display
3
Header viewing direction
Flat
4
Outlet type
Phoenix terminal
5
Output type
4~20mA with relevant contact
Particular Requirements for Product List:
Code
Configuration type
Configuration name
T1
Working voltage
220VAC/DC
T2
Display type
Backlight LED
T3
Header viewing direction
Look up or look down
T4
Outlet type
Aviation socket
T0
Special requirement
Pls list photos
Range
Selected by selection
Working voltage
24VDC, 220VAC/DC
Max power
5W (24VDC), 6W (220VAC/DC)
Temperature
<±0.07%FS/10
Stability
0.10%FS/year
Output signal
4~20mA
Alarm number
0~7
Contact capacity
5A/250VAC, 5A/30VDC
Load resistance
<750Ω
Insulation resistance
When 100VDC, ≥100MΩ
Outlet type
Phoenix terminal, aviation socket
Display type
LED, 5+8 bit with rod column LCD display
Header viewing direction
Flat, look up or look down
Sealing material
Viton
Environment
-20~60℃, ≤95%RH, avoid corrosive gas
Protection class
IP65
2 Watch window
 It is selectable, displayed directly.

IEC 61000-4-2:2001:Electrostatic Discharge Immunity Test  Class 3
IEC 61000-4-3:2002: Radiated, Radio-frequency, Electromagnetic Field Immunity Test. Class 3
IEC 61000-4-4:2004: Electrical Fast Transient Immunity Test, Class 3
IEC 61000-4-5:2005: Surge Immunity Test, Class 3